Vue de la page 38
OPERATIONS
Testing Outputs
350-7951 Quadra Users Guide 31
. . . . .
6. Review the list in detail, and note the timing parameters that most
closely match the specifications of your monitor.
7. Load the timing parameters for the selected output. Type:
OPTMLOAD <output #> <register #> Enter
8. Verify that the parameters are loaded by querying the command and
the output. Type:
OPTM <output #> Enter
9. Repeat from step 1 to set up additional outputs.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TESTING OUTPUTS
This section provides instructions for using the “TestPattern” command. For a
selected output channel, you can enable a variety of internal test patterns and
quickly check your Quadras outputs.
Use the following steps to test each output:
1. Ensure that the display(s) that you want to test are connected to
Quadra outputs, and that their output formats have been set as outlined
in the “Setting Output Format
” section.
2. Request help text for the command. Type:
H TP Enter
This action displays the command’s parameters and variables.
Figure 3-4.
Help Text — Test Pattern Command
3. To test a single output, type:
TP <output #> [test pattern] Enter
S Example: To display color bars on output 2, type:
TP 2 BARS Enter
4. To test all outputs, type:
TP ALL [test pattern] Enter
S Example: To display the grid on all outputs, type:
Vue de la page 38