COMMAND LINE INTERFACE
Command Summary
350-7951 Quadra Users Guide 72
. . . . .
SERIAL PORT
. . . . . . . . .
COMMANDS
Serial Port Commands are used to control the baud and echo settings. A
summary is listed below. Click the desired command to access detailed
instructions.
Refer to the “Serial Port Commands Descriptions
” section for a complete
description of all serial port commands.
SERIAL PORT COMMANDS DESCRIPTIONS
The table below lists all serial port commands, their arguments and detailed
descriptions.
Table 4-10.
Serial Port Commands Summary
Command Description
BAUDrate
Sets the serial port baud rate.
ECHO Turns the serial echo On/Off.
HANDShaking
Sets the flow control mode.
Table 4-11. Serial Port Commands Descriptions
Command Arguments Description
BAUDrate [9600 | 19200 | 38400 |
57600 | 115200]
Sets the serial port baud rate. The value is
automatically saved in NVRAM.
Default: 9600
ECHO [ON | OFF] Turns the serial echo On/Off. The value is saved
in the NVRAM. The echo is only present on
commands typed and sent to the unit from the
serial port. There is no echo on a Telnet
connection.
Note: The Echo setting has no effect on
responses issued by the
Quadra; responses are
always visible, regardless of the echo status.
Default: ON
HANDShaking [HW | SW] Sets the flow control mode for the serial port.
The HW option provides hardware
handshaking.
The SW option provides for software
XON/XOFF flow control.